MOSO® perforated strip masonry reinforcement has been examined by the Institute of Integral Building Construction, Minden: "All tests resulted in a breaking load value at least
3 times higher compared to the mathematical working load.
Ribbed bars produced no larger breaking loads than the test specimens reinforced with the corresponding MOSO® perforated strip masonry reinforcement.
The first crack in ribbed bar BST 500 S reinforced test specimens occurred at approximately 60% of the total breaking load, while with MOSO® perforated strip masonry reinforcement the first crack appeared only at the ultimate limit state. This is due to the good "anchoring" of the perforated strip with the mortar (this oozes through the holes when the tape is inserted in the mortar)." *
* Quote from the Institute of Integral Building Construction, Minden test report
| Perforated strip profile size | 50 x 0.5 mm |
| Stock lengths rolled | 25, 50, 100 and 200 m |
| Weight per meter | 0.156 kg |